At its core, IPMI (Intelligent Platform Management Interface) is an open standard (specifically IPMI 2.0) for out-of-band server management, while iDRAC (Dell) and iLO (Hewlett Packard) are proprietary implementations that extend IPMI functionality. Think of IPMI as the foundation protocol, with vendor-specific solutions building additional features on top.
// Example IPMI command via ipmitool
ipmitool -I lanplus -H 192.168.1.100 -U admin -P password power status
// Equivalent iDRAC REST API call (Dell)
GET https://<iDRAC-IP>/redfish/v1/Systems/System.Embedded.1
// Equivalent iLO REST call (HPE)
GET https://<iLO-IP>/redfish/v1/Systems/1
Feature | IPMI | iDRAC | iLO |
---|---|---|---|
HTML5 Console | No | Yes (Enterprise) | Yes (iLO 5+) |
Redfish API | Partial | Full | Full |
Virtual Media | Basic | Advanced | Advanced |
Power Monitoring | Basic | Per-rail metrics | Detailed analytics |
For cross-vendor scripts, stick with IPMI commands via ipmitool
. However, when automating Dell-specific workflows, leverage iDRAC's Redfish endpoints. For HPE hardware, iLO's PowerShell cmdlets often provide the most robust control:
# HPE iLO PowerShell example
$cred = Get-Credential
Connect-HPiLO -Server 192.168.1.101 -Credential $cred
Get-HPiLOPowerMeter | Select-Object AveragePower
While IPMI 2.0 supports AES-128 encryption, iDRAC 9 and iLO 5 implement TLS 1.2+ by default. Always disable IPMI over LAN if not needed, and configure vendor-specific security features:
# Disabling IPMI LAN channel (Dell)
racadm config -g cfgIpmiLan -o cfgIpmiLanEnable 0
# Enabling iLO TLS 1.2 only (HPE)
Set-HPiLOSSOSetting -Setting TLSProtocol -Value "TLS_1.2"
Modern implementations expose RESTful endpoints for programmatic control. Here's how to reboot a server using each protocol's API:
// IPMI via Redfish (generic)
POST /redfish/v1/Systems/1/Actions/ComputerSystem.Reset
{
"ResetType": "GracefulRestart"
}
// iDRAC specific implementation
POST /redfish/v1/Systems/System.Embedded.1/Actions/ComputerSystem.Reset
{
"ResetType": "GracefulRestart",
"@Redfish.SettingsApplyTime": "Immediate"
}
// iLO extended properties
POST /redfish/v1/Systems/1/Actions/ComputerSystem.Reset
{
"ResetType": "GracefulRestart",
"Oem": {
"Hpe": {
"PostState": "PowerOn"
}
}
}
When working with enterprise servers, three terms frequently surface in remote management discussions: IPMI
, iDRAC
, and iLO
. While they serve similar purposes, their implementations and capabilities differ significantly.
Intelligent Platform Management Interface (IPMI
) is an open standard (IEEE 748) for out-of-band server management. It provides:
// Example IPMI command to check system status
ipmitool -H 192.168.1.100 -U admin -P password chassis status
Major server manufacturers have built proprietary solutions on top of IPMI:
Dell's iDRAC (Integrated Dell Remote Access Controller)
iDRAC offers enhanced features beyond base IPMI:
# Using racadm (iDRAC CLI tool) to configure
racadm -r 192.168.1.101 -u root -p calvin set BIOS.SysProfileSettings.PerfProfile PerfOptimized
HP's iLO (Integrated Lights-Out)
iLO provides similar functionality with HP's unique additions:
# Example iLO REST API call (via curl)
curl -k -H "Content-Type: application/json" -X POST \
-d '{"Action": "ResetServer"}' \
https://ilo-address/redfish/v1/Systems/1/Actions/ComputerSystem.Reset/
Feature | IPMI | iDRAC | iLO |
---|---|---|---|
Virtual Console | Basic | HTML5/Java | HTML5/Java |
API Support | Limited | RESTful | Redfish |
Storage Management | No | Yes | Yes |
Power Monitoring | Basic | Detailed | Detailed |
Choose IPMI when working with cross-vendor environments or custom servers. Use iDRAC/iLO when you need:
- Advanced hardware monitoring
- Vendor-specific diagnostics
- Integrated lifecycle management
Common issues and their solutions:
# For IPMI connection problems:
ipmitool -I lanplus -H hostname -U username -P password mc reset cold
# For iDRAC authentication issues:
racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 2 newpassword