In HPE ProLiant servers like the DL360p Gen8, the NAND flash memory serves as persistent storage for critical management components:
// Example of data stored in iLO NAND:
1. iLO firmware and configuration
2. System event logs (SEL)
3. Hardware inventory data
4. Boot-time diagnostic results
5. Persistent network settings
The documented error 'Embedded Flash/SD-CARD failure' typically manifests in these operational impacts:
- iLO resets to factory defaults after power cycles
- Loss of historical hardware logs (critical for RCA)
- Inability to store custom monitoring policies
- Potential failure during firmware updates
Use the HPE RESTful Interface Tool to diagnose:
# Python example using python-redfish-utility
from redfish import RedfishClient
client = RedfishClient(base_url='https://ilo-ip', username='admin', password='')
client.login()
health = client.get('/redfish/v1/Managers/1/')
print(health.dict['Oem']['Hpe']['iLOSelfTestResults'])
For out-of-warranty systems where board replacement isn't feasible:
- External logging:
# Configure remote syslog in iLO (SSH example) ssh administrator@ilo-ip "set /map1/logging1/dest=syslog \ host=logserver.example.com port=514 proto=udp"
- Persistent configuration backup:
# Export iLO settings periodically curl -X GET -k -u admin:password \ https://ilo-ip/rest/v1/Managers/1/BackupRestoreService/BackupFiles/ \ -o ilo_config.xml
For environments with multiple affected servers:
# Ansible playbook snippet for automated health checks
- name: Verify iLO NAND status
hosts: hpe_servers
tasks:
- name: Get iLO health
uri:
url: "https://{{ inventory_hostname }}/redfish/v1/Managers/1/"
method: GET
user: "{{ ilo_user }}"
password: "{{ ilo_pass }}"
validate_certs: no
register: ilo_health
- fail:
msg: "NAND failure detected"
when: "'EmbeddedFlash' not in ilo_health.json.Oem.Hpe.iLOSelfTestResults"
In HPE ProLiant servers like the DL360p Gen8, the NAND flash memory serves as persistent storage for:
- iLO firmware and configuration settings
- System event logs (SEL) and diagnostic data
- SD card redundancy controller (when present)
- Critical boot parameters and hardware inventory
# Typical dmesg errors when NAND fails
[ 123.456789] hpilo: Embedded Flash Manager initialization failed
[ 123.456790] hpilo: NAND controller timeout (status=0xFFFF0001)
[ 123.456791] mmcblk0: error -110 sending status command
The most common operational impacts we've seen:
- iLO settings reset to defaults after reboot
- Loss of historical sensor data and logs
- Intermittent iLO disconnections during heavy I/O
- Failed firmware updates through iLO interface
For servers out of warranty, the Python Redfish utility provides ways to mitigate issues:
# Sample Python to force iLO reset without physical power cycle
import redfish
ilo = redfish.redfish_client(
base_url='https://ilo-ip',
username='admin',
password='password'
)
ilo.login()
# Graceful reset
response = ilo.post('/redfish/v1/Managers/1/Actions/Manager.Reset/',
body={'ResetType': 'GracefulRestart'})
# For stubborn cases - equivalent to power cord pull
response = ilo.post('/redfish/v1/Systems/1/Actions/ComputerSystem.Reset/',
body={'ResetType': 'ForceOff'})
time.sleep(30)
response = ilo.post('/redfish/v1/Systems/1/Actions/ComputerSystem.Reset/',
body={'ResetType': 'On'})
To safeguard against NAND failure:
# Export iLO config regularly (Bash example)
curl -k -u admin:password \
https://ilo-ip/rest/v1/Managers/1/BackupRestoreService/BackupConfig/ \
-o ilo_config_$(date +%Y%m%d).xml
# Schedule via cron
0 3 * * * /usr/local/bin/backup_ilo_config.sh
These symptoms indicate failing NAND requires board replacement:
- Consistent "Invalid firmware image" errors during updates
- Complete loss of iLO configuration between reboots
- Physical SD card slot becomes non-functional
- System event log shows ECC correction threshold exceeded
HPE's advisory a00048622en_us confirms this as a known hardware fault pattern in Gen8 servers.