RAID controller battery relearn cycles (commonly found in LSI MegaRAID and Dell PERC controllers) involve a full discharge-charge cycle to calibrate the battery's charge capacity. During this process:
- Write cache is automatically disabled (BBWC/BBU)
- Battery discharges to empty state (~2-4 hours)
- Controller measures actual capacity
- Full recharge occurs (~4-8 hours)
- Write cache re-enables post-calibration
The default relearn interval varies by controller model:
# Check current battery settings on Linux
MegaCli -AdpBbuCmd -GetBbuProperties -aALL
# Sample output showing 30-day interval
BBU Properties for Adapter: 0
Auto Learn Period: 30 Days
Next Learn time: 2023-12-15 02:00:00
To modify the schedule (requires controller reset):
# Disable auto-learn (not recommended)
MegaCli -AdpBbuCmd -SetBbuProperties -autoLearnMode=0 -a0
# Set custom interval (e.g., 90 days)
MegaCli -AdpBbuCmd -SetBbuProperties -autoLearnMode=1 -learnCycleIntervalDays=90 -a0
Database benchmarks show significant performance degradation:
Operation | Normal Mode | Cache-Off Mode |
---|---|---|
MySQL INSERT/sec | 12,500 | 3,200 |
PostgreSQL TPS | 8,700 | 2,100 |
Oracle OLTP | 6,200 IOPS | 1,800 IOPS |
For mission-critical systems, consider:
- Manual initiation: Trigger during maintenance windows via:
MegaCli -AdpBbuCmd -BbuLearn -a0
- Staggered scheduling: Rotate relearn cycles across server clusters
- Flash-backed cache: Upgrade to capacitors (FBWC) that don't require calibration
Dell's PERC H730/H830 controllers implement additional optimizations:
# Dell-specific battery health check (Windows)
perccli64.exe /cx show bbustatus
# Output includes predictive failure indicators
BBU Status: Optimal
Learning Cycle: Not Active
Days Until Next Learn: 14
Estimated Replacement Date: 2024-06-01
Implement proactive monitoring with these Nagios check examples:
#!/bin/bash
# Check for active learn cycle
STATUS=$(MegaCli -AdpBbuCmd -GetBbuStatus -a0 | grep "Learn Cycle Active")
if [[ "$STATUS" == *"Yes"* ]]; then
echo "CRITICAL: Battery learn cycle active!"
exit 2
fi
For Ansible automation:
- name: Check RAID battery status
hosts: storage_servers
tasks:
- name: Get battery info
command: MegaCli -AdpBbuCmd -GetBbuStatus -a0
register: bbu_status
- name: Alert if learn cycle active
fail:
msg: "Battery learn cycle detected on {{ inventory_hostname }}"
when: "'Learn Cycle Active: Yes' in bbu_status.stdout"
RAID controller battery relearn cycles (also called calibration cycles) are diagnostic procedures where the controller:
- Fully discharges the Backup Battery Unit (BBU) or CacheVault
- Measures actual capacity against design specifications
- Recharges the unit while logging degradation metrics
# Typical LSI CLI command to check battery status
storcli /c0 show all | grep -i battery
# Output example:
# BBU : Present = Yes
# BBU : Next Learn time = 30 days
# BBU : Learn State = In Progress
During the 4-8 hour relearn window, controllers automatically:
- Disable write-back caching (falling back to write-through)
- Reduce IOPS by 40-60% in database workloads
- Increase latency from ~0.5ms to 5-10ms
# MySQL performance metrics during relearn cycle
SHOW GLOBAL STATUS LIKE 'Innodb_buffer_pool_write%s';
# Typical impact:
# Innodb_buffer_pool_write_requests: 12000 → 4500
# Innodb_buffer_pool_wait_free: 5 → 320
Vendor | Default Interval | Override Method |
---|---|---|
LSI MegaRAID | 30 days | MegaCLI -AdpBbuCmd -BbuLearn -a0 |
Dell PERC | 90 days | omconfig storage battery action=disablelearn |
HP Smart Array | N/A (SMART monitoring) | Not applicable |
For critical production systems:
- Schedule manual relearns during maintenance windows:
# PowerShell script to force learn cycle $controller = Get-WmiObject -Namespace root\wmi -Class MSFC_AdapterHBAAttributes $controller.ForceBatteryLearn($false)
- Consider flash-backed cache modules (CacheVault) instead of BBUs
- Implement storage QoS to throttle non-critical workloads during calibration
Sample Nagios check for upcoming relearn cycles:
#!/bin/bash
LEARN_STATUS=$(sudo storcli /c0/v0 show all | grep "Next Learn" | awk '{print $4}')
if [ $LEARN_STATUS -lt 3 ]; then
echo "WARN: Battery learn cycle imminent"
exit 1
fi
For Ansible automation:
- name: Check RAID battery status
community.general.storcli:
command: show
options: all
register: raid_status
when: "'bbu' in raid_status.stdout"